Herunterladen Diese Seite drucken

Grohe EUROECO COSMOPOLITAN E 36 269 Montageanleitung Seite 6

Vorschau ausblenden Andere Handbücher für EUROECO COSMOPOLITAN E 36 269:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
frequency band (eg wireless devices, DECT phones, etc.
(observe manufacturer documentation)) should be avoided.
Technical data
Fitting with switched-mode power supply:
• Voltage supply:
• Power consumption:
Fitting with battery:
• Voltage supply:
®
Bluetooth
:
• Power consumption:
• Output:
®
• Bluetooth
- version:
® -
• Bluetooth
Transmission distance:
(depending on the environments)
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to Novoflex Zebra XL Grey Card,
grey side, 8x10", landscape (7 - 20cm adjustable):
• Type of fitting protection:
Thermal disinfection possible.
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Fault / Cause / Remedy
Fault
Water not flowing
Undesired water
flow
Flow rate too low
Automatic flush
does not work
3
100-240 V AC 50-60 Hz/6.75 V DC
6V lithium battery type CR-P2
Bluetooth
Cause
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
• Sensor system detection zone set too high
for local conditions
• Automatic flushing activated
• Solenoid valve defective
• Mousseur dirty
• Filter upstream of solenoid valve dirty
• Safety shutdown active
• Ambient conditions not suitable
Installation
Flush pipes thoroughly before and after
installation (observe EN 806)!
Open hot and cold water supply and check that
connections are watertight.
Operation and settings,
see technical product information, 99.0409.xxx /
2.4 W
99.0438.xxx
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
1 W
mode when the detection zone of the fitting is reached by an
®
- Class 2
approaching user.
4.0
Setting mode is automatically terminated after 3 minutes..
about 10m
Maintenance
•Shut off water supply.
60 s
•Disconnect voltage supply.
1 s
•Inspect and clean all components and replace if
necessary.
12cm
Batteries which are almost discharged are displayed
IP 59
by a flashing indicator lamp in the sensor system.
Replacement parts
A
see fold-out page I (* = special accessories)
2
2500 V
100 °C
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Clean or replace filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
- Reduce range using remote control (special
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Remove object
- Check ambient conditions with remote control
, see fold-out page I - II.
, see fold-out page II.
accessory, prod. no.: 36 407) / app
(special accessory, order no.: 36 407) in test
mode at maximum range, LED must not light up.

Werbung

loading