Herunterladen Diese Seite drucken

clage Zip HydroTap G4 BC 100/75 Gebrauchsanleitung Seite 23

Vorschau ausblenden Andere Handbücher für Zip HydroTap G4 BC 100/75:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Light intensity varies from site to site, therefore it is recommended
that a re-calibration be performed at the time of the installation.
All direct natural sun light must be shaded from the HydroTap,
during the calibration. This can be achieved by closing any nearby
curtains, blinds, etc.
Procedure
> Shield the HydroTap from any direct
sun light using a dark cloth
> With the unit in normal operating
mode
> Turn the power OFF
> Pull both tap levers to the forward
position
> Turn ON the power
> The unit will calibrate the safety
switch
> Return the levers to the neutral
position.
Red Boiling Water LED
On all the time
This indicates that the boiling water is
ready.
Flashing slowly
This indicates that the boiling water is
below the desired temperature.
Wait for the light to stop fl ashing before
dispensing water. The fl ashing light will
typically occur after switching on, or
coming out of sleep mode.
Safety Sensor Calibration
Tap LED's
Pull both levers
forward
Red LED's
23
Safety
sensor

Werbung

loading