• To replace the damaged mains cable, use
the cable type: H05V2V2-F which
withstands a temperature of 90 °C or
higher. The single wire must have a
diameter of minimum 1,5 mm². Speak to
your local Service Centre. The connection
cable may only be replaced by a qualified
electrician.
WARNING!
All electrical connections must be made
by a qualified electrician.
CAUTION!
Do not drill or solder the wire ends. It is
forbidden.
N
L
One-phase connection - 220 - 240 V~
N
L
3.4 Assembly
If you install the hob under a hood, please
see the installation instructions of the hood
for the minimum distance between the
appliances.
82
ENGLISH
220-240 V~
Green - yellow
Blue and blue
Black and brown
CAUTION!
Do not connect the cable without cable
end sleeve.
Two-phase connection
1. Remove the cable end sleeve from black
and brown wires.
2. Remove an insulation of the brown and
black cable ends.
3. Apply a new wire end sleeve of 1.5 mm²
on common cable end (special tool
required).
Cable cross section 1,5 mm²
400V 2~N
Two-phase connection - 400 V 2 ~ N
Green - yellow
Blue and blue
Black
Brown
min.
500mm
N
L1
L2
N
L1
L2
min.
50mm