EN
B4 B5 B6
L2
Switch on/off the inten-
sive ventilation (boost)
B4 B6
L4-L7
Review and cancel
L2-L7
B2 B3 B5
"Child safety feature"
Connection
Flashing „Con" – connecting.
Shining „noC" – connection lost.
Fan
speed
cont
• Selecting 4 preset speeds
• Selecting percentage value of speed (0, 20-100%)
• User menu speeds are set in intervals of 5%
• Service menu speeds are set in intervals of 1%
• Selecting 4 preset pressure values by using pressure sensor
• Maximum speed is limited by timer which can be easily set when maximum fan speed is activated (boost)
• Maximum speed can be activated using fast button. When preset maximum fan speed (boost) time is over,
previous speed is automatically restored.
• 0..10 VDC CO2 sensor can be connected for activation of maximum speed based on the given CO2 param-
eters
Temperature
• In controller, desired temperature can be set between 15 and 35°C
• Supply air and set temperatures can be displayed interchangeably (set temperature is displayed for 5 sec-
onds, then supply air temperature is displayed for 2 seconds)
Remote
control
Controller supports fully confi gurable Modbus interface. Panel can operate as master and slave device in
modbus network and also it can be fully controlled and confi gured not only via service menu but also via mod-
bus interface.
User
menu
In order to reach user menu, press down B2 and B3 for 3 seconds.
In user menu, menu items (P.01, P.02 etc.) settings are displayed sequentially. Menu item is selected using
elements B4 and B6. After pressing B5, value of selected parameter is shown and can be changed using ele-
ments B4 and B6. Press B5 to save the parameter and to return to menu.
Due to limitations of segment display, values of P.04 and P.05 are shown divided by 10, i.e. if 20 is displayed, it
means that real value is 20 x 10 = 200.
P.06 - To reset fi lter timer to press and hold for 5 seconds item B5. Also fi lter timer resets by removing A.03
alarm.
Touch element B1 to exit menu.
www.salda.lt
2 sekundes palaikyti B5.
For canceling, press down
alarms
B2 and B3 for 3 seconds.
CO2 blow off
On/off
Press down B3, B2 and
B5 for 2 seconds.
ind
ndication
n
ntrol
co
control
ol
(Modb
dbus)
L2 fl ashes. Remaining time in seconds is
shown in the segment display (for values
above 600s, time is shown in minutes).
Time is adjusted by touching B4 and B6.
Maximum BOOST running time: 180m.
(3h)
In case of alarms, L4, L5, L6, L7 fl ash
and alarm code is shown in the segment
display (A.01, A.02 etc.). You can review
alarm list by using elements B4 and B6.
After alarm is canceled, controller returns
to initial state.
L2, L3 and L7 fl ash, L4, L5, L6 light on.
Non active elements B1, B4 and B6. After
pressing unavailable button, segment
display shows "−−−"
29