Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - VOLTCRAFT CO-60 Bedienungsanleitung

Raumluft-anzeige
Vorschau ausblenden Andere Handbücher für CO-60:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

b) Air quality display in traffic light colours
Air quality is shown using a traffic light display with 3 coloured LED's. The following displays are possible:
Green LED:
The CO
-concentration is below 800 ppm. Air quality is good.
2
Yellow LED:
T he CO
-concentration is between 800 and 1500 ppm. Air quality is ok. It is recommended
2
ventilating the room soon.
Red LED:
T he CO
-concentration is above 1500 ppm. Air quality is bad. It is necessary to ventilate
2
the room.
If the warning signal is not muted, another additional audio sound is emitted.
c) Muting the audio sound.
At a CO
-concentration of more than 1500 ppm, an audio sound is emitted. This sound can be muted by
2
pressing the "MUTE"-key (4).

TROUBLESHOOTING

The display indicates "ERR3":
• The ambient temperature is lower than 0 °C or higher than +50 °C.
Confusing symbols on the display:
• Disconnect the ambient air indicator from the operating voltage.
No display:
• Check the power supply.
• E ither use the enclosed power supply or alternatively, a so-called high-power USB port that delivers a
minimum current of 500 mA.
CLEANING AND MAINTENANCE
The device requires no servicing on your part, apart from occasional cleaning.
Use a soft, antistatic and lint-free cloth for cleaning. Do not use abrasive or chemical cleaners.
Do not apply too much pressure on the display to avoid scratch marks.
DISPOSAL
Electronic devices are recyclable waste materials and must not be disposed of in the household
waste! Dispose of an unserviceable product in accordance with the relevant statutory regula-
tions.
TECHNICAL DATA
a) Ambient air indicator
General
Operating voltage ..........................................5 V/DC
Power consumption . ......................................max. approx. 180 mA
Display . ..........................................................LCD (backlit)
Measured values ...........................................Carbon dioxide, temperature and relative humidity
Operating ambient temperature . ....................0 °C to +50 °C
Ambient temperature during storage . ............-20 °C to +60 °C
Ambient humidity . ..........................................0% to 95% relative humidity, not condensing
Dimensions . ...................................................137 x 99 x 28 mm (W x H x D), without feet
Weight ...........................................................approx. 182 g
Carbon dioxide sensor
Measurement range ......................................0 - 3000 ppm
Definition . .......................................................1 ppm (0 - 1000 ppm)
Accuracy (temp. < +25 °C) . ...........................±80 ppm or ±5% of the reading
Repeatability . .................................................±20 ppm (at 400 ppm)
Influence of temperature . ...............................Typically ±0,2% of the reading per °C
Warming-up phase ........................................2 min for +22 °C
Temperature sensor
Measurement range ......................................0 °C to +50 °C
Definition . .......................................................0,1 °C
Accuracy . .......................................................±1 °C
Humidity sensor
Measurement range ......................................20% to 90% relative humidity
Definition . .......................................................1%
Accuracy . .......................................................±5% relative humidity at +23 °C
b) Power adaptor
Operating voltage ..........................................100 - 240 V/AC, 50/60 Hz
Output . ...........................................................5 V/DC, 800 mA
5 ppm (1001 - 2000 ppm)
10 ppm (2001 - 3000 ppm)
(>2000 ppm: ±7% of the reading)
or ±2 ppm of the reading per °C, referring to +25 °C
Legal notice
G
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
A ll rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
T hese operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2014 by Conrad Electronic SE.