Herunterladen Diese Seite drucken

Cognex In-Sight 8000 Serie Bedienungsanleitung Seite 10

Vorschau ausblenden Andere Handbücher für In-Sight 8000 Serie:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 79
Connect the Inputs and Outputs (Optional)
The vision system's I/O connector supplies connections for the acquisition trigger and
high-speed outputs.
Note: The vision system must be Online for the discrete inputs and outputs to
function. Refer to the In-Sight
discrete input and output lines.
Option 1: Connect the Breakout Cable
CAUTION:
A ferrite is included with the In-Sight 8405 vision system standard
components. To reduce emissions, the ferrite must be attached to the
Breakout cable.
Note:
I/O wiring or adjustments to I/O devices should be performed when
l
the vision system is not receiving power.
The Ethernet cable should be unplugged or the PoE source powered
l
down before making adjustments to the connections at the far end of
the Breakout cable.
Unused wires can be clipped short or tied back using a tie made of
l
non-conductive material.
1. If installing the In-Sight 8405 vision system, attach the ferrite around the
Breakout cable, adjacent to the strain relief on the cable.
2. Connect the Breakout cable's M8 connector to the vision system's I/O
connector.
®
Explorer Help file for details on configuring the
9

Werbung