Herunterladen Diese Seite drucken

Emerson Aventics SentronicPLUS 614 Serie Installationshandbuch Seite 9

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATION
5.2
SPECIFICATIONS
Nominal
Supply
diameter
(1)
voltage
DN
(stabilised)
(mm)
3
6
+/-10%
24 V=
12
20
(1) Residual ripple: 10 %
(2) Test conditions according to ISO 8778: temperature: 20 °C, relative inlet pressure: 6 bar, relative outlet pressure: 5 bar
Setpoint input
Feedback output
Digital output
INSTALLATION AND OPERATING INSTRUCTIONS
1.
Before putting into operation carefully check all electrical connections and the supply voltage (24 VDC ±10 %).
Overload can destroy the electronics. Recommended pre-fuse T2.0 A.
2.
The electrical connection is made with a round connector M12x1. The connector must meet the requirements
of DIN 60079-15. The product was tested with connector catalogue no. 88100729.
In order to ensure conformity with ATEX Directive 2014/34/EU, the product must be installed in such a manner
as to protect the electrical connector from mechanical stress.
WARNING:
Do not disconnect the connector while under voltage!
3.
Use shielded cables for the electrical connection of the valve. The shield, connector and control cabinet must
be EMC compliant. The valve body must be electrically connected to ground (PE, machine ground). Do not run
control cables parallel to high-voltage lines, servo-motor control cables etc.
4.
Min. wire cross-section of supply voltage cable: 0.50 mm
For longer cabling distances use larger cross-section cables as required.
5.
Make sure that the valve is under pressure when a setpoint signal is applied to the valve (applying a setpoint
signal with no pressure on the valve will cause it to overheat).
6.
The valve is factory adjusted.
7.
The product must be returned to the factory for repair.
Max. power
Max. current
(W)
(mA)
12
500
24
1000
34
1400
44
1800
: 0 ... 10 V (100 kOhm input resistance)
0 ... 20 mA / 4 ... 20 mA (250 Ohm input resistance)
: 0 ... 10 V (max. 10 mA), short-circuit protected
0 ... 20 mA / 4 ... 20 mA (max. 24 VDC)
: pnp; open collector; max. 200 mA/4.8W, short-circuit protected
HIGH (24 VDC) if feedback=setpoint
LOW (open) if feedback≠setpoint
Visit our website at Emerson.com/AVENTICS
Insulation
Degree of
K
class
protection
(Nm
0,18
0,60
F
IP 65
1,20
4,80
2
.
Flow
(2)
at 6 bar
Electrical connections
(l/min
V
3
/h)
ANR)
210
5-pin female M12 connector
700
or
1400
7-pin female DIN connector
5600
GB
9

Werbung