(Output)
PRESSURE SWITCH OUTPUT
NPN
Feedback = Setpoint
or
PNP
Feedback = Setpoint
or
NPN
Feedback ≠ Setpoint
or
PNP
Feedback ≠ Setpoint
!
CAUTION - BE SURE TO FOLLOW THESE INSTRUCTIONS!
1) The coil must only be supplied with 24 V DC ±10 % and a max. ripple of 10 % (no supply via
diode bridge). Overvoltage or a ripple rate exceeding 10 % can damage the electronics.
2) The max. current at pin 7 is 500 mA (NPN/PNP output). Pin 7 is protected against short circuit
and overload.
3) If a relay (inductive load) is connected to the pressure switch output, a freewheel diode or
a varistor must be used.
4) Do not solder unused pins on the connector.
5) In case of an interruption in the pressure supply, shut off the power supply (+24V) or switch
the set point to zero to avoid excessive heating of the coil.
6) Grounding for personal protection must be done at the PE terminal (ØM4) on the body (see
diagramme opposite).
7) The valve housing must be connected to the ground potential with low resistance via the
ground connection (ØM4). The eyelet of the grounding cable must be inserted between two
toothed washers and fastened with a screw (M4). The tightening torque corresponding to
the screw must be observed.
6
7-pin DIN connector
View on solder side
of female connector
Supply voltage
+24V
Supply voltage GND
Setpoint
10V
(or 0-20 mA or 4-20 mA)
Setpoint GND
Not used
Outlet pressure feedback
0-10V (or 0-20mA or 4-20mA)
NPN if setpoint
+ 30V max.
is reached
I = 500 mA max.
PNP if setpoint
0V
is reached
I = 500 mA max.
NPN if setpoint
+ 30V max.
is not reached
I = 500 mA max.
PNP if setpoint
is not reached
I = 500 mA max.
Visit our website at Emerson.com/AVENTICS
INSTALLATION
Connector on
electronic card
NPN
PNP
NPN
PNP
PE
ØM4
2