INSTALLATION
1.
DESCRIPTION
The S
PLUS
entronic
intelligent electronics. The S
displacement or angle positions. It supplements the S
The S
PLUS
entronic
are provided to cover a wide flow range. Versions with different body and seal materials can be used in many
sectors, e.g. the food industry, medical technology etc.
Cascaded control allows setting up complex control loops using the DaS software (Data Acquisition Soft-
ware). Digital control offers many advantages during installation and start-up of the S
extended possibilities to adapt it to various applications.
All pressure and exhaust ports are the same size, which allows for short response times when the pres-
sure is increased or decreased.
Digital pressure control in a closed loop: An internal pressure sensor measures the outlet pressure. The
outlet pressure is adjusted in real time.
The control parameters can be changed with the DaS software (from DaS release 5.00): The DaS soft-
ware (Data Acquisition Software) ensures the variability of the parameters used by the valve. This flex-
ibility allows the valve to be adapted to the most various applications, and its response time, overshoot
and precision to be optimised.
After having set the optimum parameters, you can save them in a project file for your personal use or
send them to our Product Support for future serial production.
ATEX approval for the version with M12 connector without display:
1.1
CATALOGUE NUMBER
- Digital electronic
PLUS
S
entronic
- with external pressure supply
PLUS
S
entronic
B:
Control panel
A = M12 without display - non-explosionproof
D = M12 with display - non-explosionproof
E = M12 without display - explosionproof (ATEX)
F = DIN connector, 7-pin, with display - non-explosionproof
G = DIN connector, 7-pin without display - non-explosionproof
A:
VERSION (ports), body
0 = DN6
(G 1/4), Alu
1 = DN12 (G 1/2), Alu
2 = DN20 (G 1), Alu
3 = DN6
(ISO 1), Alu
4 = DN6
(NPT 1/4"), Alu
5 = DN12 (NPT 1/2"), Alu
S:
SETPOINT
0 = 0 ... 10 Volt
1 = 0 ... 20 mA
2 = 4 ... 20 mA
I:
FEEDBACK
1 = Feedback output 0 ... 10 Volt
2 = Feedback output 0 ... 20 mA
3 = Feedback output 4 ... 20 mA
4 = Feedback input 0 ... 10 Volt
5 = Feedback input 0 ... 20 mA
6 = Feedback input 4 ... 20 mA
with integrated digital control loop combines the latest in pneumatics technology with
series allows precise control of pressure, flow, force, velocity and
PLUS
entronic
is available in 14 standard pressure ranges from 100 mbar to 50 bar. Four nominal sizes
q
II 3D Ex tc IIIC T135°C Dc X
q
II 3G EX ec IIC T4 Gc X
0 ≤ Ta ≤ +50 °C
pressure regulator valve
6 1 4 3 5 7
6 1 4 3 5 9
6 = DN20 (NPT 1"), Alu
7 = DN3
(G 1/8), Ms
8 = DN6
(G 1/4), Ms
9 = DN3
(NPT 1/8), Ms
A = DN6
(NPT 1/4"), Ms
C = DN6
(G 1/4), VA
2)
H = DN6
(G 1/4), Ms
3)
3)
3)
Visit our website at Emerson.com/AVENTICS
series.
D
entronic
B A S I D P P
B A S I D P P
PP: PRESSURE RADNE
Relative pressure
40 = 0 - 100 mbar
50 = 0 - 500 mbar
60 = 0 - 1 bar
02 = 0 - 2 bar
03 = 0 - 3 bar
05 = 0 - 5 bar
06 = 0 - 6 bar
10 = 0 - 10 bar
12 = 0 - 12 bar
16 = 0 - 16 bar
20 = 0 - 20 bar
3H = 0 - 30 bar
5H = 0 - 50 bar
V3 = 0 - (-1) bar
D:
DIGITAL OUTPUT
1 = Pressure switch output
PNP ± 5 %
PLUS
valve and
entronic
Max. allowable
Vacuum (relative)
pressure (bar)
V3 = 0 ... -1 bar
2
Shut-off valve
2
2
3
8
8
12
12
14
1)
18
1)
22
2
40
)
2)
60
Notes:
1)
Only for DN3 and DN 6
2)
Only for DN6, Ms
3)
Only for 614357..., not for 614359...
Other versions available on request.
GB
3

Werbung

loading