Notes on the documentation, 1 General information
2 Safety instructions, 3 Fitting
Notes on the documentation
The following information is intended to help you
throughout the entire documentation.
Further documents apply in combination with this instal-
lation manual.
We accept no liability for any damage caused by fail-
ure to observe these instructions.
Attachment and storage of the documents
Please pass this assembly manual on to the owner of the
system in order for him or her to store it so that it is
available whenever it is required.
Symbols used
Please observe the safety instructions in this manual for
the installation of the neutralisation device!
Danger!
e
Immediate danger to life and limb!
a
Caution!
Potentially dangerous situation for the product
and environment!
h
Note!
Useful information and instructions.
• Symbol indicating the required action
1
General information
The neutralisation device provides neutralisation of the
condensed water from boilers and/or flue pipe systems
made of stainless steel, plastic and ceramic.
The condensed water from the condensing unit is fed
into a vessel. In the vessel there is neutralising medium
which lifts the pH value of the condensed water to a
neutral level. The neutralisation medium can be replaced
via a removable cover.
The neutralised condensed water can be fed into the
drainage system.
Only for units with Part No.: 301374:
A feed pump pumps the neutralised condensed water
through a drain hose, controlled by the level of water,
over a height difference of up to 2 metres. It can then be
directed into the sewage system from this location.
The operating conditions of the unit are displayed. In the
event of a fault the boiler is temporarily switched off via
an error signalling line which is connected directly into
the System ProE Switching Field of the condensing boil-
er until the fault is resolved. This prevents condensed
water from coming out of the unit into the room.
2
2
Safety instructions
e
Danger!
Only for units with Part No.: 301374:
Switch the power supply off before opening the
cover on the feed pump control!
Danger!
Switch the condensing boiler off before opening
the cover (mains switch and fuses)!
3
Fitting
e
Danger!
Switch the condensing boiler off before fitting
the device (mains switch and fuses)!
Caution!
a
The neutralisation device must be mounted hor-
izontally. The bottom of the neutralisation de-
vice must be at least 90 mm lower than the
condensed water drain connection on the con-
densing boiler.
1
14
12
11
10
Fig. 3.1 Overview of the neutralisation device with feed pump,
Part No.: 301374
Installation manual for neutralisation device 0020056625_00
2
3
4
2x
5
4x
6
7
8
9