T R O U B L E - S H O O T I N G
While touch the hot water, hands feel a little tingling
Possible causes:
1.
The appliance is not properly earthed
Corrective actions:
1.
Connect the earth properly
No heating
Possible causes:
1.
No power supply
2.
The knob didn't toward to hot water position
3.
The power boardkeep off mode
4.
Manual Reset thermal cut-out
5.
Heating element failure
Corrective actions:
1.
Correct power supply
2.
Toward the knob to hot water position
3.
Press (9 to turn on the power board
4.
Contact local service
5.
Contact local service
Too high outlet temperature
Possible causes:
1.
Setting temperature is too high
2.
Thermal Cut-out cut off
Corrective actions:
1.
Touch "-" to decrease the temperature
2.
Contact local service
Outlet water flow gest smaller & smaller
Possible causes:
1.
Inlet strainer or bubbler was blocked
2.
Inlet water pressure become lower
Corrective actions:
1.
Clean strainer or bubbler
missionair
2.
Increase the inlet water pressure