I N S T R U C T I O N
TECHNICAL DATA
Model number: Mission Air® FLOW 3,3 kW
Voltage: 220-240V
Rated frequency: 50/60Hz
Power: 3300W
Temp. setting range: 30-50°C ( 86-122°F)
Overheat protection: 53°C
Thermal cut-out: 120°C, manual reset
Rated Pressure: 0MPa
Water Pressure: 0,02-0,6Mpa
Hot Water Flow: 1L-5L
Inlet Connector: G1/2"
INSTALLATION GUIDELINE
The installation must be in compliance with the National Electrical Code, your local
electrical and plumbing codes.
1.
Makesure the appliance is intact,and the fittings are complete.
2.
Please make sure the main power supply, water pressure, grounding condition, ammeter
and wire reach the standard of installation requirement.
3.
The appliance must be connected to properly groundeddedicated branch circuitsof
proper voltage rating.
4.
If you will not use thetap for long time, please switch off the leakage protection plug.
5.
Position the unit uprightwith all plumbingconnections at the bottom of the unit.
6.
During the installation, water supply must be test before the power supply.