Herunterladen Diese Seite drucken

Mission Air HYDRO FLOW 3,3 KW DARK Betriebs Und Installationsanleitung Seite 28

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 33
T R O U B L E - S H O O T I N G
Inlet and outlet fittings leaking
Possible causes:
1.
Fittings not tight
2.
Rubber washer worn-out
Corrective actions:
1.
Tighten fittings
2.
Replace rubber seal ring
Keep the hand shank in close mode, but there is still water come out
Possible causes:
1.
Valve core failure
2.
Valve body failure
Corrective actions:
1.
Contact local service
2.
Contact local service
Outlet water flow bifurcate / Outlet water flow is too small
Possible causes:
1.
Filter net of bubblerscale or blocked by impurity
2.
Inlet water pressure is too low
Corrective actions:
1.
Disconnect the bubbler and clean the filer net
2.
Increase the water pressure
There is noisy while turn off the water flow
Possible causes:
1.
Water pressure is too high
2.
Turn off the hand shank too fast
3.
The water pipe wasn't fixed well
Corrective actions:
1.
Turn down the water flow
2.
Turn off the hand shank again
3.
Reconnect the pipe