Herunterladen Diese Seite drucken

HANSGROHE Aqittura M91 SodaBase 76835000 Gebrauchsanleitung, Montageanleitung Seite 12

Vorschau ausblenden Andere Handbücher für Aqittura M91 SodaBase 76835000:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
• Half-yearly (earlier if necessary): Perform chemical cleaning and change filter.
• After 4 years: Replace the seal on the CO2 pressure reducer.
• After 7 years: Replace CO2 pressure reducer.
Technical data / Wifi (see page 78)
Device:
Type:
Band width:
Transmitting power:
Output volume of chilled / sparkling water:
Cooling capacity:
Temperature of filtered water:
Weight:
Protection class:
Power consumption (cooling phase):
Power consumption (water output):
Power consumption (idle phase):
Noise emission LpA:
Water connection:
Type shield position / data:
Hansgrohe SE hereby declares that the SodaBase wireless unit type complies with
Directive 2014/53/EU. The full text of the EU Declaration of Conformity can be
accessed on the following website: pro.hansgrohe.com
Troubleshooting Table
• A red lit LED on the tap indicates a fault. In this case, check the error code on
the device and follow the instructions in the operating manual or the hansgrohe
home app.
• A yellow lit LED on the tap indicates that cleaning is in progress.
Malfunction
Too little water
No CO2 in water
Little CO2 in the water
No CO2 in water after flushing or cleaning.
Device does not work / none of the LEDs light up or
flash.
Tap LED lights up white, LED 1 lights up, LED 6 pulses
slowly (E304)
Tap LED lights up white, LEDs 1 and 6 flash quickly
(E303)
CO2 cartridge/cylinder empty although the device
still shows remaining level
Tap LED lights up white, LED 1 and 8 pulses slowly
(E302)
Tap LED lights up white, LEDs 1 and 8 flash quickly
(E301)
Tap LED pulses white, LED1-5 pulse simultaneously
(E307)
Malfunction during chemical cleaning: Tap LED
flashes red, LED 1-5 and 8 flash quickly (E408)
Fault during flushing after chemical cleaning: Tap
LED flashes red, LED 1-3 and 8 flash quickly (E409)
LED 1+6 flash quickly (E404)
Tap LED flashes red, LED 2+6 flash quickly (E405)
12
English
• A white lit LED on the tap indicates an operating message; these are cleaning,
• Reset (reset error): Hold down key 6 + 8 simultaneously for approx.
SodaBase
WLAN
2412 - 2472 MHz
Max. 25 mW (14 dBm)
2 l/min
7 l/h
4 - 12°C
20 kg
I
(LED 1-8)
180 W
240 W
3 W
38 dB (A)
Cold water
(see page 78)
Cause
- Dirt trap screen dirty
- Jet former dirty
- CO2 cartridge/cylinder is empty
- CO2 pressure set too low (2 kg cylinder)
- CO2 cartridge / cylinder not completely screwed in - Completely screw in CO2 cartridge / cylinder
- Dispensing temperature too high
- Low water hardness / unfavourable filter type
- CO2 pressure set too low (2 kg cylinder)
- CO2 cartridge removed during flushing or cleaning. - Draw and dispose of 1 litre of soda water after
- Power supply disturbed
- Fuse blown
- CO2 cartridge/cylinder low
- CO2 cartridge/cylinder is empty
- A partially full CO2 cartridge/cylinder was inserted
or fill level not immediately reset at time of
replacement
- Seal of CO2 pressure reducer defective
- Service life of the filter soon reached
- Service life of the filter exceeded
- Chemical cleaning required due to 6 month cycle or
long period of non-use
- Power failure. Power supply disturbed.
- Mains connection not plugged in correctly.
- Water supply interrupted
- Power failure, power supply disturbed
- Connection cable not plugged in correctly
- Water supply interrupted
- No connection between tap and SodaBase
- Water inlet has been connected to the hot water line - Connect water inlet to cold water pipe
flushing, water dispensing, portioned water dispensing, etc.
3 seconds after an error has occurred and has been corrected. If the error
persists, disconnect the device from water and power and inform the Service
Department (see page 80).
6
1 2 3 4 5
min
max
°
°
CO
CO
C
C
2
2
7
Remedy
- Clean the dirt trap screen in the T-piece
- Clean the jet former
- Change CO2 cartridge/cylinder. (see page 73)
- Increase CO2 pressure to 0.4 MPa (4 bar) (external
cylinders only)
- Lower the dispensing temperature if possible
- Increase the water hardness if possible (e.g. adjust
water softening system, where necessary use a
mineralisation filter
- Increase CO2 pressure to 0.4 MPa (4 bar) (external
cylinders only)
chemical cleaning
- Insert mains plug into socket
- Check plug at the back of the device
- Pull out the mains plug and replace the fuse with a
new one of the same value.
- Ensure availability of new CO2 cartridge/cylinder
- Change CO2 cartridge/cylinder
- Insert new CO2 cartridge/cylinder and reset level on
SodaBase
- Replace the seal on the pressure reducer
- Have a new filter ready
- Replace filter
- Carry out chemical cleaning
- Chemical cleaning was interrupted. Restart chemical
cleaning (see page 76)
- Restart flushing process (press filter key briefly)
- Check connection cable and plug in correctly
8
FILTER
FILTER

Werbung

loading