Problem Chart
5
Problem
Radio connection
cannot be
established or
connection
breaks off
repeatedly.
No power.
No sound;
receiver RF
indication does
not light.
No receiver
sound; receiver
group indication
lights.
Received signal is
noisy or contains
extraneous
sounds with
transmitter on.
Remedy
• Place the receiver at least 1 meter above the
ground and not too close to lateral walls.
• Avoid sources of interference such as metal
surfaces or electronic devices (e.g. computer, CD
player).
• For optimum reception, keep the transmitter at least
1 meter away from the receiver and avoid
obstacles.
• Check batteries of the microphone; charge
transmitter/receiver.
• Make sure transmitter and receiver are switched on.
• Check microphone battery indication to ensure that
batteries are providing power. Replace batteries if
necessary.
• Make sure that receiver is in line of sight of
transmitter. If necessary, reduce distance between
transmitter and receiver.
• Apply signal to transmitter and observe receiver's
group indication. If it lights up, the problem is
elsewhere in the sound system.
• Check for proper connection between receiver and
mixer/amplifier.
• Check microphone's battery indication to ensure
that battery is providing power; charge the
transmitter if need be.
• Remove local sources of HF interference, such as
lighting equipment.
• Two transmitters may be operating on the same
frequency. Locate and turn one off.
• Signal may be too weak. If possible, move receiver
closer to transmitter.