Pressure fluctuates.
The motor stops suddenly.
7. TECHNICAL SPECIFICATIONS
Product reference: 08135
Product: Hydroboost 1400 Essential
Power: 1400 W
Voltage: 220-240 V~, 50/60 Hz
Rated pressure: 7 MPa (70 bar)
Max. pressure: 10.5 MPa (105 bar)
Vibration: ≤ 2.5 m/s
2
Nominal flow rate: 5.5 l/min
Max. flow: 7.1 l/min
Most common specific weight configuration: 4.8 kg
5 ºC - 50 ºC IPX5
Technical specifications may change without prior notification to improve product quality.
Made in China | Designed in Spain
8. DISPOSAL OF OLD ELECTRICAL AND ELECTRONIC APPLIANCES
This symbol indicates that, according to the applicable regulations, the
product and/or cells must be disposed of separately from household waste.
When this product reaches the end of its shelf life, you should dispose of the
cells/batteries/accumulators and take them to a collection point designated
by the local authorities. 
Consumers must contact their local authorities or retailer for information
concerning the correct disposal of old appliances and/or their batteries.
Compliance with the above guidelines will help protecting the environment.
HYD RO BO O S T 1 40 0 E S S E N T I A L
70
The pump is sucking in air.
The nozzle is clogged.
The valves are dirty or worn.
Hydraulic seals are worn.
The extension cord is too long
or short.
The thermal safety
switch has tripped due to
overheating.
Check that hoses and
connections are airtight.
Clean them with the nozzle-
cleaning needle.
Contact the Technical Support
Service of Cecotec.
Remove the extension cord.
Make sure that the mains
voltage matches the voltage
stated on the rating label of
the appliance.