Technical specification
Description
Tank Capacity
Dimension (Width x Height x Depth)
Weight empty
Diameter of water connections
Diameter of condensate drainage connections
Type of corrosion protection
Type of internal tank protection
Max Working pressure
Setting range of the water temperature
Operating temperature range of the heat pump
Refrigerant R134a
Refrigerant volume in equivalent tonnes
Refrigerant design pressure (high side / low side)
Voltage
Frequency
Total Max power consumption
Max power consumption by heat pump
Max power consumption by heating element
Protection rating
Air flow rate (H/M)
Available static pressure
Unit
WH20S F5
L
200
mm
580 x 1625 x 582
kg
100
-
-
-
Impressed Current Cathodic protection
-
MPa
°C
°C
kg
0.65
T.eq.CO
0.930
2
MPa
Power supply
V
Hz
W
W
W
Air side
m
/min
6.7/4.4
3
Pa
90
EN
WH27S F5
270
580 x 2008 x 582
119
G 3/4"
3/4" 1/2"
Ceramic coated
1
35 to 60
-5 to 48
0.75
1.072
2.0 / 0.9
230
50
2600
550
2050
IPX1
6.7/4.4
90
35

Werbung

loading

Diese Anleitung auch für:

Wh27s f5Wh27sWh20s