Herunterladen Diese Seite drucken

LG WH20S F5 Betriebsanleitung Seite 21

Wassererhitzer mit wärmepumpe
Vorschau ausblenden Andere Handbücher für WH20S F5:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 109
Safety Controls
!
CAUTION
You must have a qualified person
investigate the cause of the high
temperature condition and take corrective
action before placing the water heater in
service again.
There is temperature limiting control(ECO)
that is located above the upper heating
element. If the water temperature becomes
excessively high, the temperature limiting
control(ECO) shuts off the power to the
heating elements.
Once the control opens, it must be reset
manually.
To reset temperature limiting control(ECO):
1
Turn off the power by opening the circuit
breaker or removing the fuses.
2
Remove the front decor and upper
element cover.
Press the red ECO RESET button.
3
Insulation Blanket Kits
External insulation blanket, available to the
general public, for water heater is not
necessary.
The manufacturer's warranty does not cover
any damage or failure caused by installing or
using any type of unauthorized energy-saving
or other devices.
The manufacturer is not responsible for any
injury or loss resulting from the use of such
unauthorized devices.
!
CAUTION
If local codes require application of any
external insulation blanket kit to water
heater, it will require careful attention
so as not to restrict the proper function
and operation of this appliance:
- DO NOT block the air openings of the
water heater.
- DO NOT cover or attempt to relocate the
information or warning labels attached to
the water heater.
- DO NOT cover the control panel, T&P
relief valve, drain valve, and junction box.
- Inspect the blanket frequently.
EN
21

Werbung

loading

Diese Anleitung auch für:

Wh27s f5Wh27sWh20s