5. Fill the lubricant on both sides up to the maximum fill level.
6. Screw the filler and drain screws back in.
5.4 Connecting the vacuum side
Risk of crushing from rotating parts
Fingers and hands may be caught by rotating pistons within the connection flange. This results in se-
vere injuries.
► Keep limbs out of the reach of the roots pump.
Property damage from intake of solid particles
During commissioning, there is a risk of damage to the suction chamber from dirt from the system or
the pipes.
► Use a suitable protective strainer ("start-up strainer") in the intake flange.
► Ensure that this strainer is only removed when the risk of solid particles entering the vacuum
Required tools
● Ring spanner, WAF 13 with flange DN 160 ISO-F
● Ring spanner, WAF 30 with flange DN 150 PN16
Connecting the vacuum side
1. Degrease the connection flange.
2. Clear welded lines of any scaling, loose particles etc. prior to installation.
3. Route the piping between the vacuum pump and vacuum chamber so that it remains as short as
4. Select a larger nominal diameter for pipe lengths > 5 m.
5. Support or suspend the piping to the vacuum pump so that no piping system forces act on the
6. Always use all prescribed bolts for fastening the flanges and consider the prescribed pressure
5.5 Using splinter shield
Pfeiffer Vacuum centering rings with splinter shield in the vacuum flange protect the roots pump against
foreign matter from the vacuum chambers. The pumping speed is reduced according to the passage
guide values and the size of the vacuum flange.
– Once full, lubricant overfills the fill level limiter, and drips out of the drain hole.
– Fill level is visible in the center of the sight glass.
WARNING
pump can be excluded.
– Observe any pumping speed decrease.
possible; at a minimum, the nominal diameter of the pump flange.