Herunterladen Diese Seite drucken

Belden HIRSCHMANN EAGLE40-07 Referenzhandbuch Seite 229

Vorschau ausblenden Andere Handbücher für HIRSCHMANN EAGLE40-07:

Werbung

Netzsicherheit
[ Netzsicherheit > DPI > ENIP Enforcer > Objekt ]
Tab. 5:
Class-ID
0x05 = Connection
0x06 = Off-Link Connection
Manager
0x07 = Register
0x08 = Discrete Input Point
0x09 = Discrete Output Point
0x0A = Analog Input Point
0x0B = Analog Output Point
228
Class-IDs für Funktionstyp
1
read-write
(Forts.)
Service-Codes
0x05 = Reset
0x08 = Create
0x09 = Delete
0x0D = Apply Attributes
0x0E = Get Attribute Single
0x10 = Set Attribute Single
0x11 = Find Next Object Instance
0x4B = Connection Bind
0x4C = Production Application Lookup
0x4E = Safety Close
0x54 = Safety Open
0x01 = Get Attributes All
0x02 = Set Attributes All
0x0E = Get Attribute Single
0x10 = Set Attribute Single
0x4C
0x4E = Forward Close
0x52 = Unconnected Send
0x54 = Forward Open
0x56 = Get Connection Data
0x57 = Search Connection Data
0x59
0x5A = Get Connection Owner
0x5B = Large Forward Open
0x0E = Get Attribute Single
0x10 = Set Attribute Single
0x01 = Get Attributes All
0x02 = Set Attributes All
0x0E = Get Attribute Single
0x10 = Set Attribute Single
0x01 = Get Attributes All
0x02 = Set Attributes All
0x0E = Get Attribute Single
0x10 = Set Attribute Single
0x01 = Get Attributes All
0x02 = Set Attributes All
0x0E = Get Attribute Single
0x10 = Set Attribute Single
0x01 = Get Attributes All
0x02 = Set Attributes All
0x0E = Get Attribute Single
0x10 = Set Attribute Single
RM GUI EAGLE40-07
Release 4.6 06/2023