Defrosting
Timing of defrosting (Abb.1)
The electronic control panel is pre-set to automatically execute four
defrosting cycles within twenty four hours. Its timer will reset to the time of
the initial first start-up. In order to modify the start time for the defrost cycle
to the desired time, it is sufficient to follow these directions, press the
defrosting key, for 3 seconds, the unit will start defrosting at that time, and
another cycle will follow sic hours later. Automatic removal defrost system
in all the models.
7. MAINTENANCE
Periodic cleaning of cell and condenser
Before starting cleaning put the switch off and disconnect the plug. Is
important to clean the internal basin at least once a week by following the
directions see initial cleaning. Clean the condenser located above the unit,
behind the command panel, at least once a week. Before starting cleaning,
close and protect the unit, then remove the dust which has deposited on
the front surface of the condenser using a broom or vacuum cleaner.
Inactivity oft he device
During periods of inactivity, put the switch off and disconnect the plug,
accurately clean the unit, as per periodic cleanings, allow air to circulate in
the cell by covering the unit with a material that allows the device to
transpire.
8. OPERATIONS IN THE CASE OF FAILURES
If the device is not functioning, make sure that:
the plug has been correctly inserted into the socket;
the supply cord is not damaged.
If the pre-set temperature is not reached make sure that:
the command switch is turned on;
the electronic control panel is correctly regulated (see setting the
cell temperature);
the device is neither in the defrosting phase nor the post-defrosting
phase;
the evaporator is not covered with frost;
the condenser is not blocked with dust;
the device is not located near heat sources or its condensing unit is
not well-aired;
the stored foods or other objects do not inhibit the proper closing of
the unit;
the device is not working in anomalous conditions (overloaded,
loaded with hot food, or loaded in a way that prevents proper air
circulation).
If the device leaks water make sure that:
11