Herunterladen Diese Seite drucken

Abicor Binzel iCOOL 1200 Bedienungsanleitung Seite 26

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10 Faults and troubleshooting
10 Faults and troubleshooting
► Observe the documentation for the welding components.
► Note the warranty documentation provided.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
Tab. 3
Faults and troubleshooting
Fault
Device does not function
Too little or insufficient
coolant flow
Cooling capacity too low Ventilator is defective.
High running noise level
Leakage
EN - 12
Cause
Power supply is interrupted.
Motor/pump is defective.
No coolant in the coolant tank.
Coolant level is too low.
Bottleneck or foreign object in the cooling circuit. ► Check the coolant hoses and connections.
Pump fuse is defective.
Pump is defective.
Coolant circuit is interrupted.
Air in the coolant circuit.
Pump is defective.
Cooling unit is dirty.
Surrounding objects prevent the flow of air.
Coolant level is too low.
Pump is defective.
The connections have leaks.
Inner hoses have leaks.
Pump is defective.
Coolant temperature is too high.
Troubleshooting
► Switch on the power supply.
► Check the electrical system and contact
customer service as needed.
► Replace the motor/pump.
► Contact the service team.
► Replace the fuse.
 9.3 Replacing the fuse on page EN-13
► Add coolant.
► Top up coolant.
► Flush the cooling circuit.
► Replace the fuse.
 9.3 Replacing the fuse on page EN-13
► Check the coolant circuit connections and
contact customer service as needed.
► Check the coolant hoses for damage and
replace them as needed.
► Bleed.
 6.2.2 Bleeding the device on page EN-10
► Contact the service team.
► Contact the service team.
► Blow out the cooling unit with dry
compressed air.
► Install the device so there is sufficient distance
from other objects.
► Top up coolant.
► Contact the service team.
► Check for dirt and clean as needed.
► Contact the service team.
► Contact the service team.
► Replace the hoses.
► Contact the service team.
► Clean the cooling unit.
► Check the fan for proper function.
iCOOL 1200