References marked on instrument or in
instruction manual:
Warning of a potential danger, comply with in-
struction manual.
Caution! Dangerous voltage. Danger of elec-
trical shock.
Continuous double or reinforced insulation
complies with category II IEC 61140.
Symbol for the marking of electrical and elec-
tronic equipment (WEEE Directive).
Conformity symbol, the instrument complies
with the valid EU directives.
CAT III
Measurement Category III is applicable to test and
measuring circuits connected to the distribution
part of the building's low-voltage Mains installa-
tion.Examples are measurements on distribution
boards (including secondary meters), circuit-
breakers, wiring, including cables, bus-bars, junc-
tion boxes, switches, socket-outlets in the fixed in-
stallation.
Introduction
The contact-free voltage tester MAGNO Voltfix
has been developed for voltage testing on insula-
ted cables and conductors. For testing, no elec-
trical connection to UUT is required. A second
connection, e.g. to neutral or ground is not
necessary. The second instrument function is the
recognition of a magnetic field, e.g. of relays,
contactors, and magnetic valves.