Herunterladen Diese Seite drucken

Zibro SC 1832 Installations-Handbuch Seite 67

Vorschau ausblenden Andere Handbücher für SC 1832:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
instal_SC1832.qxd
06-05-2010
ATTENTION
If need suspending installation, the installation bracket should accord with all technical
requirements. The installation wall should be strong enough or actions to reinforce should be
taken. The connection between bracket and wall, bracket and the air conditioner should be firm,
stable and reliable. In case of any doubts or uncertainty do not attempt to install the unit but
have the support calculated and engineered by a skilled engineer.
For capacities ≤ 7,0 kW: never place the outdoor unit over 5 meters higher or over 5 meters lower than the
indoor unit.
Settlement of outdoor unit
Anchor the outdoor unit with bolts, lock washers and nuts ø 10 mm or ø 8 mm tightly and horizontally on
a concrete or rigid mount.
Model
3.03
≤ 5.2 kW
www.zibro.com/download
> 5.2 kW
≥ ø85 mm
< 20
< 20
cm
cm
10:55
Pagina 67
Strong
wind
Fig. 10
A (mm)
530
S1825 - S1833 - S1847
Installation & Service Manual
560
≥ 20
≥ 20
cm
cm
B (mm)
Air inlet
290
335
Fig. 11
The last 20 cm of the refrigerant pipe, close to the connec-
tor must be kept straight. Bending can cause leakage and is
not covered by the warranty.
Air inlet
Air ourlet
4
67

Werbung

loading