instal_SC1832.qxd
06-05-2010
2. Drill a hole in the wall
1.
Determine hole positions according to the diagram detailed in Fig.5. drill one (1) hole (≥ 85 mm) slan-
ting slightly downwards to outdoor side, this will prevent water to come indoors.
2.
Always use wall hole conduit when drilling metal grid, metal plate or the like.
3. Connective pipe and drainage installation
1.
Always run the drain hose sloping downward all the way. Do not install the drain hose as illustrated
below.
2.
When connecting extension drain hose, insulate the connecting part of extension drain hose with a
shield pipe, do not let the drain hose slack.
4. Indoor unit installation
1.
Pass the piping through the hole in the wall.
2.
Put the upper claw at the back of the indoor unit on the upper hook of the installation plate, move the
indoor unit from side to side to see that it is securely hooked.
3.
The female half can be easily past through by lifting the indoor unit with a cushioning material bet-
ween the indoor unit and the wall. Get it out after finishing it.
4.
Push the lower part of the indoor unit up on the wall. Then move the indoor unit from side to side, up
and down to check if it is hooked securely.
10:55
Pagina 65
.
Do not put the end of drain hose
Do not block water flow by a rise.
Upper Hook
Lower Hook
Cushion
material
Indoor unit
Ponding box
Connective
Pipe room
cable
Connective
pipe
Wrapping
Drain hose
Fig. 9
into water.
Fig. 8
belt
.
4