Outside temp)
For example, Set room temp = 25° C, Max BTW temp = 43° C, Initial BTW temp = 20° C
a. When outside temp= 20° C, Target buffer tank temp = 20+(43-20)/35x(25-20)=23° C
b. When outside temp= 0° C, Target buffer tank temp = 20+(43-20)/35x(25-0)=36° Cc.
c. When outside temp= -15° C, Target buffer tank temp = 20+(43-20)/35x(25+15)=46° C
d. When Air temperature sensor failure, in OFF status, in DHW mode, and in cooling mode, the unit doesn't run
according to heating curve.
e. When the unit is working in ECO mode, it only works according to the heating curve, can't set temperature
by controller or App.

10.5 Remote control with App

Scan the QR code to install the APP of "Smart Life", after installing the APP, the software
mobile phone.

1. Software registration

Ensure the unit and mobile phone connected to a Wi-Fi. Please complete registration step
by step if new user.
After registration is complete, please log in to the software by user name and password you have set, the heat
pump and mobile phone should be connected to WIFI.
Press simultaneously
LARGE HOUSEHOLD APP in the menu, select SMART HEAT PUMP WIFI on the list, next, select AP MODE in the
top right menu
,
and
,
, select ADD DEVICE on the APP on your smartphone, select
will display on you