10.3 Parameters settings

Parameter changes may only be made by trained personnel authorised by the manufacturer.
1.In main menu, press
set parameters. Press
2. In parameter setting menu, if there is no operation for 30 seconds, will automatically exit parameter setting
and back to main menu. Or press
Item Description
Water difference to start compressor in hea-
b01
ting mode
Water difference to start compressor in coo-
b02
ling mode
b03 Max. set temperature in heating mode
b04 Min. set temperature in heating mode
b05 Max. set temperature in cooling mode
b06 Min. set temperature in cooling mode
b07 Water temperature compensation
b08 Circulation running mode
b09 Circulation pump interval time
Inlet and outlet water temperature
b10
difference protection value
b11 Working mode
b12 Power lost memory function
b13 Air temperature to start E-heater
b14 Air temperature to enter EVI
b15 Type of fan
Water temperature compensation
b16
function
b17 Set room temperature
b18 Initial BTW temperature
b19 Max. BTW temperature
b20 Extend defrosting interval 1
b21 Extend defrosting interval 2
b22 Defrosting enter temp 1
b23 Defrosting enter temp 2
b24 Defrosting running time
b25 Defrosting exit temperature 1
b26 Defrosting exit temperature 2
b27 Anti-legionella interval time
b28 Anti-legionella temp
button for 3 seconds to enter parameter setting menu, press
button to save setting..
button to back to main menu.
Default
Unit
Range
value
3
°C
0~15
3
°C
0~15
60
°C
20~60
15
°C
10~20
32
°C
20~60
8
°C
7~20
0
°C
-9~9
2
0~2
5
min
0~99
13
°C
5~40
3
0~1
1
0~1
-15
-30~20
8
0~10
1
0~3
1
0~1
25
°C
15~25
20
°C
15~25
43
°C
24~50
0
min
-30~50
0
min
-30~50
9
°C
-30~50
8
°C
-30~50
12
min
6~16
18
°C
12~25
5
°C
4~11
144
h
0~9999
70
°C
1~99
or
button to
Remark
0: run 2 mins every b09 mins
1: run as compressor run
2: always run
0: heating
1: heating+DHW
2: heating+cooling
3: heating+cooling+DHW
After setting, it needs to be
powered off to take effect.
0: off
1: on
0: DC
1: single speed
2: double speed
3: three speed
After setting, it needs to be
powered off to take effect.
0: no
1: yes
When set to 0,
this function is not
available