F - MAINTENANCE AND UPKEEP
2.1 - HISTORY OF EVENTS AND ERROR

CODES

• During operation, events may occur that may be
malfunctions of the motor drive or consequences
of user actions.
• Each event has a different code.
• This code is displayed by a combination of red
LEDs that are on, off or flashing on the MENU
0 display.
• When OK or PROG are pressed, this code is
deleted. However, the last 4 codes generated are
memorised, and can be viewed in a history.
• To access them, press OK twice, then use the "+"
and "–" buttons to scroll through the memorised
codes.
To diagnose any problems, here is the list of codes
and their meaning:
: LED off
: LED on
: Flashing LED
There are two types of code: Error (E) or
Information (I). N.B. an error requires action from
the installer to correct the motor drive problem.
LED
An obstacle has
L1
L2
L3 L4
been detected in M1
when closing.
An obstacle has
L1
L2
L3 L4
been detected in M2
when closing.
L1
L2
L3 L4
The photocell beam
has been obstructed.
L1
L2
L3 L4
been detected in M1
when opening.
L1
L2
L3 L4
been detected in M2
when opening.
Motor M1 is not
connected or
L1
L2
L3 L4
incorrectly connected
(contact failure).
Check connections.
Motor M2 is not
connected or
L1
L2
L3 L4
incorrectly connected
(contact failure).
Check connections.
EN
36
Description
Type
An obstacle has
An obstacle has
L1
L2
L1
L2
L1
L2
L1
L2
L1
L2
I
L1
L2
I
I
I
L1
L2
I
E
L1
L2
E
The maximum
operating time has
been reached (a
L3 L4
motor is idle and the
stop has not been
reached?). Check
that the motor is
engaged.
Panel M1 closed
before panel M2.
L3 L4
Increase the time
interval between the
movement of both
panels.
Three
obstacles detected
L3 L4
in a row during
opening. Check
the gate movement
area.
Three obstacles
detected in a row
L3 L4
during closing.
Check the gate
movement area.
The main power
supply has been cut
during a movement
L3 L4
phase OR the battery
is too weak for
proper
operation.
Self-learning is
not valid (it was
never performed
L3 L4
or a setting that
requires repetition
of self-learning has
been changed). Start
self-learning.
Automatic closure
has been cancelled.
Generated if the gate
re-opens 3 times (10
in collective mode)
L3 L4
after a photocell has
been obstructed
during automatic
closure OR if the
beam was obstructed
for more than 3
minutes.
The gate control
input (2B) is
L3 L4
permanently
earthed. Check the
connections.
E
E
E
E
E
E
E
E