Herunterladen Inhalt Inhalt Diese Seite drucken

Maximum Opening Angle - avidsen V250 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 128
C - INSTALLATION

2.1 - MAXIMUM OPENING ANGLE

The installation of the actuators depends on the desired opening angle which depends on distance D (the
distance between the axis of the hinge and the inner side of the post).
Normal case
• If D<170mm
distance D
Special cases
• If D>170mm and if the structure of the posts allows, the posts must be cut so that D' is equal to 170mm.
• If D <0mm, place a shim thick enough so that D' is equal to 0mm.
Determine the opening angle of each panel based on the data in the following table.
The opening angle may be different for each panel but must never be less than 40°.
D
opening
angle
Inner side of the property
EN
10
post
D
view from above
D
post
D'
post
D'
central stop
opening
angle
view from above
For
D
opening up to
90°
100°
110°
side
120°
stop
Distance D
(in mm)
from 0 to 170 max
from 0 to 110 max
from 0 to 60 max
from 0 to 20 max

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

114166

Inhaltsverzeichnis