HAZARD ANALYSIS

REGULATION
Installation of a motorised gate or a motor
drive on an existing gate within the framework
of "Residential" type use must be compliant
with directive 89/106/EEC concerning building
products.
The reference standard used to check this
compliance is EN 13241-1 which EN 12453 which
specify the motorised gate safety methods and
components to reduce or completely eliminate
hazards to people.
The installer must train the end user on the correct
operation of the motorised gate, and the trained
user must train the other people likely to use the
motorised gate, using this guide.
It is specified in standard EN 12453 that the
minimum protection of the gate's primary edge
depends on the type of use and the type of control
used to set the gate in motion.
The gate motor drive is a press control system, i.e.
simply pressing one of the control parts (remote
control, key selector, etc.) sets the gate in motion.
This gate motor drive is equipped with a force
limiter which complies with appendix A of EN
12453 standard, within the framework of use with a
gate that is compliant with the specifications given
in this chapter.
The specifications of EN12453 standard therefore
enable the 3 following use cases, as well as the
minimum levels of protection:
• Press activation with visible gate
Minimum level of protection: Force limiter only.
• Press activation with non-visible gate
Minimum level of protection: Force limiter and 2
pairs of photocells to protect the gate's opening
and closing.
• Automatic control (automatic closure)
Minimum level of protection: Force limiter and 1
pair of photocells to protect the gate's automatic
closing.
The flashing light is an essential safety component.
The photocell type safety devices and their correct
operation must be checked every six months.

C - INSTALLATION

SPECIFICATIONS OF THE GATE TO
MOTORISE
This motor drive can automate swing gates up to
1.75m wide and 2.20m high and weighing 150kg.
These maximum dimensions and weights are for
an openwork-type gate and for use in an area that
is not very windy. For solid gates or a use in an
area with significant wind speed, it is necessary to
reduce the maximum values indicated above for
the gate to be motorised.
SAFETY CHECKS ON THE GATE
The motorised gate is strictly for residential use.
The gate must not be installed in an explosive or
corrosive atmosphere (presence of gas, flammable
smoke, vapour or dust).
The gate must not have locking systems (latch,
lock, bolt, etc.).
The hinges of the gate must be on the same axis
and the axis must be vertical. The posts supporting
the gate must be strong and stable enough so that
they do not bend (or break) under the weight of the
gate. Without the motor drive, the gate must be
in good mechanical conditions, correctly balanced
and open and close without friction or resistance.
Greasing the hinges is recommended. Check that
the fastening points of the different components
are in locations that are sheltered from shock and
that the surfaces are solid enough. Check that the
gate does not have any part protruding from its
structure. The central stop and side stops must be
appropriately fastened so as not to give way under
the force exerted by the motorised gate.
If installation does not correspond to one of the
cases shown in the guide, contact us so that we
can provide all the components necessary for
proper installation with no risk of damage.
The motor drive cannot be used with a driven part
that has a door.