C - INSTALLATION
Important: The two marks should be at the middle of the rigid part of the gate so that the actuator is
completely horizontal.
• Drill through the gate from side to side, respecting the locations marked above.
• Attach the gate mounting bracket to the gate with M8 round head screws square under the head, the
length must be adapted to the thickness of the gate, flat washers and M8 locknuts, as shown in the
following figure.

3 - INSTALLING THE SWITCHGEAR

The switchgear must be mounted to the post where the 230Vac power comes from.
• To ensure proper operation of the motorisation, the length of the actuator cables must not exceed 8 m per
actuator. Therefore, the switchgear must be mounted less than 6 m from each actuator.
• Use two screws to install and mount the switchgear in the defined location.