3.3.1. CLOSING TIME INTERVAL

In general, on closing, one gate panel closes over
the other. This panel is controlled by the motor
connected to output M1 of the electronic card. To
ensure that the panels close in the correct order,
the system arranges for the panel of motor M2 to
come to a stop 2.5 seconds before the panel of
motor M1. If the gate is solid and exposed to the
wind, panel M2 may be stopped by the wind and
panel M1 may be helped by the wind on closing. In
this case, panel M1 may catch up to panel M2 and
the panels may close in the wrong order.
If this occurs, the time interval between the panel
movements during closure may be increased.
To adjust this time interval, follow the
procedure below
• Press PROG for 3 seconds. L0 will flash once
and L1 will turn on.
• Press PROG for 3 seconds. L0 will flash twice.
• Press PROG for 3 seconds. L0 will flash 3 times.
• Press OK. The number of LEDs that turn on will
indicate the set value.
• Use the "+" and "-" buttons to change this value
(see table below).
• Press OK to confirm this value. All the LEDs will
turn on and off to confirm the operation.
+
L1
L2
L3
L4
Temps préclignotement
OK
PROG
L1
L2
L3
L4
Temps préclignotement
– et + pour régler la valeur
0 : 1 sec (par défaut)
1 : 3 sec
OK
L1
L2
L3
L4
Enregistre réglage
MENU 0
D - BEGINNING OPERATION
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
Note: During opening, there is also a time
interval between the panel movements, but
this time interval is fixed and is equal to 2.5
seconds.

3.3.2 - FLASHING LIGHT PRE-FLASHING TIME

The flashing light is an important safety

component. It starts when a command to set the
gate in motion is received by the electronic card.
The gate is set in motion around one second after
a command is received.
In certain use cases, it is better that the time
between receiving a motion command and the
start of the manoeuvre is longer. It is possible to
increase this time to 3 seconds.
To set the pre-flashing time, follow the
procedure below
• Press on PROG 2 or 3 times and the green LED
should be switched on (only the green LED)
• Press "PROG" for 3 seconds. L0 will flash once
and L1 will turn on.
• Press "PROG" for 3 seconds. L0 will flash twice.
• Press "PROG" for 3 seconds.
• Press "+" once. L2 will turn on instead of L1.
• Press OK.
• If L1 is switched off, the time is 1 second. Press
"+" to increase it to 3 seconds, then OK to
confirm.
• If L1 is switched on, the time is 3 seconds. Press
"–" to reduce it to 1 second, then OK to confirm.
L4
2.5 s (par défaut)
L4
3 s
L4
3.5 s
L4
4 s
L4
4.5 s
31