If (B – D) ≤ X ≤ (B – C), it is qualified and the display has normal display
If X > (B – C), it is overweight and the display flickers.
Acquisition of target value
Press
long until the display shows [TARGET], and then press
If F2.6 = 0, press
If F2.6 = 1, the display shows [000000], to request manual change of target value. After change, press
and quit setting interface.
FUNCTION OF ACCUMULATION SCALE F2.1 = 4
Operation method
In normal weighing state, when the scale is in , add weight to the scale and press
[Add--] progress bar, it indicates that the current display weight is included accumulated value, and then it returns to normal weighing
state. If the display shows [--no--] for a second, and returns to the normal weighing state, it indicates operation is invalid. Reason:
1. Between two accumulation operations, the scale must have back-to- process, otherwise, accumulation is refused. 2. Accumulation
operation is effective only when display weight≥F2.2 is set. 3. The scale is in dynamic state.
Adjustment, clearing and printing of accumulated value
In normal weighing state, press
then the display shows current total accumulated value [A 9.500] and flickers. To clear accumulated value, press [Pr 20.5], to make
flicker weight be 0. Press
Attention: set whether to be over detailed data or accumulated data in F4.6.
FUNCTION OF COUNTING SCALE F2.1 = 5
Instrument display
[c 128], showing current quantity.
Sampling method
1. Check whether the scale is in , if not, press
2. Place materials counted on the scale.
3. Press
long until the display shows [SAMPLE], and then press
quantity counted just now, and press
If F2.6 = 1 (if this function is activated, you will have to indicate the unit weight, it would be easier without activating it), the display
shows [000000], input sample weight. Press
4. In this function, press
FUNCTION OF ANIMAL SCALE F2.1 = 6
Operation method
In normal weighing state, place the animal on the weighing platform and its weight must be ≥threshold value set in F2.2. Press
instrument will collect data sampling. After sampling, the average value of sampling data will be locked, showing A X.XXX. Press
to print; press
16
, the instrument will take the weight on current scale as the new target value and quit the setting interface.
on operation panel for more than 2 seconds, the display will show [Zero] for a second, and
to print accumulated data. Press
for confirmation. The instrument saves sampling data and quits the sampling interface.
to display switch between quantity and weight.
or
to quit the interface.
to show current target value and flicker.
to quit the interface.
for setting.
. If F2.6 = 0, the display shows [PC5 00]. Input the
, the instrument saves setting data and quits sampling setting interface.
USER'S MANUAL ARX
to save setting data
on operation panel, if the display shows