F3.4 Real-time clock, date setting
F3.5 Real-time clock, time setting
F4 PRINTER CONFIGURATION (NON MODIFY)
F4.2.4 Printing languages selection
CHI: CHINESE \ ENG: ENGLISH \ FRA: FRENCH \ ESP: SPANISH \ ITA: ITALIAN \ POR: PORTUGUESE
F5 MAINTENANCE AND SERVICE
F5.1 Key test
Instrument display¡, press
, [lb/kg] and
in order, and the instrument displays
key test.
F5.2 Display screen test
All strokes of meter display will have self-inspection, to observe whether there is lacks of strokes.
Press
or
F5.3 Display current internal code
The display will show internal code of current instrument after smoothing. Press
7. FUNCTION DESCRIPTION
WEIGHT MAINTENANCE FUNCTION F2.1 = 1
Operation method
In normal weighing state, press
indication lamp is on. Only when weight setting value≥F2.2 is displayed, weight maintenance operation is effective. Otherwise, it will
return to weighing state after invalid operation information [--no--] is shown for a second.
If weight is in locked state, press
lamp is off.
If it is in weight locking state, refuse to remove skin, clear skin and setting operation.
PERCENTAGE DISPLAY F2.1 = 2
Display specification
Display [Pr 20.5], representing 20.5 %.
Pr = current actual weight / range ×100%.
Press
to display switch in percentage and weight.
CHECK WEIGHT AND SELECTION SCALE FUNCTION F2.1 = 3
Function description
Set parameters such as F2.2 = A, F2.3 = B, F2.4 = C and F2.5 = D.
When display weight is X.
If X ≤ A, do not conduct check weight and selection.
If X < (B – D), it lacks of weight, and the display flickers.
,
,
,
to quit test of display screen.
on the operation panel, the will instrument lock display weight of the current scale, and "Hold"
again to cancel locking of weight and return to normal weighing state, and "Hold" indication
,
,
,
,
USER'S MANUAL ARX
and
, press
to quit
or
to quit the interface.
EN
EN
15