1.After unit starts, select your desired operation mode.
2.Press
/
button to change TIMER mode.
TIME
TIME
ON
OFF
Press
button "
ON
0.5 " will appear ,after 10 seconds
TIME
ON
the time display will be blank.
Press
button "
OFF
0.5 " will appear ,after 10 seconds
TIME
OFF
the time display will be blank.
Then select your desired TIMER mode (TIMER ON or
TIMER OFF ). "
"or "
3.Press
/
button to set time.
TIME
TIME
ON
OFF
Press the button for each time, setting time in the first
12 hours increased by 0.5 hour every time, after 12
hours,increased by 1 hour every time.
4.Confirm timer setting
After adjust the time,press
time ON or OFF button will not flash any more.
5.Cancel timer setting
Press the
button the time display eliminated.
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be
achieved.
HEALTH Operation
(This function is unavailable on some models.)
Press HEALTH button , the remote controller will show
and then achieve to the health function.
Press again this HEALTH button , the health function will be
cancelled.
The anion
generator
in the airconditioner can generate
a lot of anion effectively ba
and anion in the air and also to kill bacteria and speed
up the dust sediment in the room and finally clean the
air in the room.
"will flash.
button and confirm the
lance the quantity of position
EUROPEAN REGULATIONS
CONFORMITY FOR THE MODELS
Climate:T1
Voltage:230V
CE
All the products are in conformity with the following
European provision:
2014/53/EU(RED) 2014/517/EU(F-GAS)
2009/125/EC(ENERGY)
2006/1907/EC(REACH)
ROHS
The products are fulfilled with the requirements in the
directive
2011/65/EU
of the European p arliament and of
council on the Restriction of the use of Certain Hazardous
Substances in Electrical and Electronic Equipment (EU
RoHS Directive)
WEEE
In accordance with the directive
parliament, herewith we inform the consumer about the dis-
posal requirements of the electrical and electronic products.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this
symbol.This means that electrical and electronic
products shall not be mixed with unsorted
household waste. Do not try to dismantle the
system yourself : the dismantling of the air
conditioning system,treatment of the refrigerant, of oil and of
other part must be done by a qualified installer in
with relevant local and national legislation. Air conditioners
must be treated at a specialized treatment facility for reuse,
recycling and recovery. By ensuring this product is disposed
of correctly, you will help to prevent potential negative cons-
equences for the environment and humen health. Please
contact the installer or local authority for more information.
Battery must be removed from the remote controller and dis-
posed of separately in accordance with relevant local and
nationl legislation.
WIFI
-Wireless maximum transmit power (20dBm)
-Wireless operating frequency range (2400~2483.5MHz)
- support standards: IEEE 802.11b , IEEE 802.11g ,
IEEE 802.11n
IMPORTANT INFORMATION REGA-
RDING THE REFRIGERANT USED
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
R32
1=
2
2=
1
1+2=
F
E
This product contains fluorinated greenhouse gases covered by
the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R32
GWP* value:675
GWP=global warming potential
Please fill in with indelible ink,
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product
charging port (e.g. onto the inside of the stop value cover).
A contains fluorinated greenhouse gases covered by the Kyoto
Protocol
B factory refrigerant charge of the product: see unit name plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
2010/30/EU(ENERGY)
of the European
2012/19/EU
accordance
A
kg
B
kg
C
kg
D
and
4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis