V44 Duo Installation & User manual

What is V44 Duo?

V44 Duo is a compact code lock with two relay outputs.
This makes V44 Duo capable of controlling two doors – or
one door and an optional function, e.g. a light switch. Either
a four- or a six-digit code can be used to open connected
doors. All programming is done from the keypad.
Open two doors using one code
The advantage of using two relay outputs is that two func-
tions can be activated at the same time, using only one
code. For example, the code can open the lock and turn on
a light switch at the same time.
Another setup is to connect the code lock to two doors.
One code is programmed to operate both doors, while the
other only opens one of the doors.
If the code is programmed to open both doors, you can set
V44 Duo so that the other door does not open until the first
door has been opened and closed (see the Delay section).
For each code, choose whether to activate both relay
outputs, only one or only the other.
Disable the codes whenever needed
V44 Duo offers the possibility to disable codes at certain
times. For example, the cleaning staff's access to the build-
ing can be limited to certain hours, while tenants/staff can
have access to the door 24 hours a day.
By connecting two time clocks to V44 Duo, three different
time zones can be used to control the codes: one controlled
by time clock 1, one controlled by time clock 2 and one that
is valid 24 hours a day, i.e. no time control.