20

Delay on/off

When this function is activated, the following happens: If a
code is programmed to open two doors, lock relay 2 is not
activated until door 1 has been opened and closed.
If door 2 is opened with the exit button, door 2 has to be
opened and closed before door 1 can be opened.
Note that door contacts must be connected and that Door
control must be activated for this to work.
This is how to activate Delay:
1
Press B and enter the current password.
2
Enter A80.
3
Enter 1.
To deactivate Delay, press 0 in step 3 instead.

Erase the memory

This is how to erase all programmed information (including
the password):
1
Press B and enter the current password.
2
Press SW1 on V44 Duo's circuit board.
3
Enter 112186.
4
Enter 112186 once again. The memory is now erased
and V44 Duo goes back to the factory settings.