Before use, make sure the system has been installed correctly by an
authorised dealer according to the given instructions.
These operating instructions describe how to operate the system using the indoor and outdoor units.
As for the operation of other products such as radiator, external thermo controller, underfl oor units and multi split indoor unit,
refer to the operating instructions of each product.
Some functions described in this manual may not be applicable to your system.
Must use water that complies with European water quality standard 98/83 EC. The lifespan of the Tank Unit will be shorter if
groundwater (include spring water and well water) is used.
The Tank Unit shall not be used with the tap water containing contaminants such as salt, acid, and other impurities which may
corrode the tank and its component.
Consult your nearest authorised dealer for further information.

System overview

Remote Controller
Note:
Not recommended to open the Front Plate.
(For authorised dealer/specialist use only)
The illustrations in this manual are for explanation purposes only and may differ from the actual unit.
They are subject to change without notice for future improvement.

Operating conditions

Water outlet temperature (°C)
(Min. / Max.)
Outdoor ambient temperature (°C)
(Min. / Max.)
When the outdoor temperature is out of the range in the table, the heating capacity will drop signifi cantly and the outdoor unit may
stop operating for its protection.
The unit will restart automatically after the outdoor temperature returns to the specifi ed range.
*
Above 45 °C (Other indoor unit run in heat mode below ambient -5 °C) or 55 °C (Air to water unit on only at all ambient Or other
1
indoor unit run in heat mode above ambient -5 °C) only possible with backup heater operation.
*
Above 45 °C (Other indoor unit run in heat mode below ambient -5 °C) only possible with backup heater operation.
2
*
Under heat recovery mode, the outdoor ambient operating range from -15 °C to 46 °C.
3
Solar Panel
Indoor Unit
(Tank Unit)
Front Plate
Multi Split Heat Pump
Outdoor Unit
HEATING (TANK)
- / 65*
1
-15 / 35
-15 / 46*
3
Multi Split
Indoor Unit
Radiator
Shower
Fan Coil
Unit
Floor
Heating
Power Supply
HEATING (CIRCUIT)
20 / 55*
2
-15 / 35
EN
3