Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning The Surfaces; Cleaning The Fire Pot; Cleaning Firex; Guarantee - Ravelli 500 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39
!
!
PLEASE FOLLOW THE INSTRUCTIONS FOR CLEAN-
ING SHOWN BELOW CAREFULLY! FAILURE TO OB-
SERVE THEM MAY LEAD TO PROBLEMS IN THE FUNC-
TIONING OF THE STOVE.

10.1. Cleaning the surfaces

To clean the surfaces on the painted metal parts, use a wet cloth in
water or at the most, water and soap.
Important: the use of aggressive detergents or diluents can damage
the surfaces of the stove.
10.2. Cleaning the fire pot before and after each lighting
You must check that the fire pot, where the combustion takes place,
is clean and that no waste or residue blocks the holes, in order to
always guarantee excellent combustion of the stove, thus avoiding
possible overheating, which could causes changes in the colour of
the paint or flaking of the door. as well as failing to light the stove.
Clean basket with all the
holes clearly visible
Only a clean fire pot can guarantee that the pellet stove functions
without problems. During functioning. deposits may be formed, which
have to be immediately eliminated.
It is easy to see when the fire pot has to be cleaned! It only needs a
glimpse, each day, before switching on. For minor cleansing, it can
be left in the stove, but if the residue is difficult to remove, it has to be
extracted from its housing and the waste scraped out.
The residue of ash depends on the quality of pellets used.
Important: even with a new batch of pellets, although using the same
brand, there may be differences during combustion and therefore
they may dirty to a greater or lesser extent.
Correct cleaning, done on a daily basis, allows the stove to burn
optimally and to have a good yield, avoiding malfunctioning which in
the long term could require technical assistance to reset the stove.
10.3. Cleaning the FIREX 600
All Ravelli products have a combustion chamber made with FIREX
600, a material based on vermiculite, the result of research and
development by Ravelli. The main features of FIREX 600 are resistant
to heat, its lightness and excellent insulating capacities, improving
the combustion and performance of the stove.
During combustion, FIREX 600 turns white, due to an effect called
PYROLYSIS, making the flame clear and shining. If the combustion
is regulated in an optimal way, the FIREX 600 interior always remains
clean and white.
The condition of FIREX 600 is therefore a thermometer to
understand whether the combustion is good or not.
FIREX 600 LIGHT – EXCELLENT COMBUSTION
FIREX 600 DARK – POOR COMBUSTION
Firex 600 does not require special maintenance, it only has to be
dusted with a brush to remove the ash that is deposited during
combustion.
Abrasive sponges to clean to most resistant waste should not be
used as they could compromise the thickness of the FIREX600 panel,
Pag.24
Basket needing cleaning
with the holes blocked by ashes
creating critical points of breakage.
The tube of the vacuum cleaner should not be used in direct contact
with FIREX 600.
Wet cloths should not be used to clean FIREX 600.
FIREX 600 is resistant to heat but not to knocks; handle with care if
moved.
FIREX 600 may show a slight abrasion after a few hours of functioning,
this is perfectly normal as the flame creates microgrooves in the
panel without compromising it.
The duration of FIREX 600 depends only on how maintenance is
carried out.
The pellet stove is a generator of heat with a solid fuel and as
such requires servicing by qualified personnel at least once
a year at the start of the season. This maintenance has the
purpose of ascertaining and ensuring the perfect efficiency of
all the components.
We recommend you draw up an annual contract for maintenance
of the product with your installer/dealer.

11. GUARANTEE

11.1. Certificate of Guarantee

Ravelli thanks you for the confidence you have placed in it with the
purchase of one of our pellet stoves and invites the purchaser to:
examine the instructions for the installation, use and maintenance
of the stove.
examine the conditions of guarantee shown below.
The enclosed coupon must be filled in and stamped by the installer.
If this does not occur, the product will not be covered by the guar-
antee.

11.2. Conditions of guarantee

The limited guarantee covers defects of manufacturing materials, on
condition that the product has not been broken due to an incorrect
use, carelessness, wrong connections or errors of installation.
The following are not covered by guarantee:
vermiculite (Firex 600);
the glass of the door;
the fibre gaskets;
the painting;
the stainless steel combustion basket;
the resistance;
the cast majolica
any damage caused by inappropriate installation and/or handling of
the stove and/or shortcomings by the consumer.
The use of poor quality pellets or of any other material could damage
components of the stove causing the termination of their guarantee
and the annexed responsibility of the manufacturer.
The pellets which meet the requisites listed in the chapter on them
should be used.
All damage caused by transport are not acknowledged, therefore
please carefully check the goods on receipt, immediately advising
the dealer of any damage.
All the manufacturer's guarantees are shown here and no complaint
may be made to the manufacturer according to any other guarantee,
report or request.
The guarantee coupon must be detached and sent to the following
address within eight days of purchase:
Ravelli srl - Via Kupfer 31 - 25036 Palazzolo s/O Brescia IT-
ALY

11.3. Information and problems

For any information or problems, please contact your dealer or
service centre, the only people who can meet any request you may
have problem, if necessary, who can intervene directly.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis