START PROG: This parameter shows the time PROGRAM 1 and 2
go on. STOP PROG : This parameter shows the time PROGRAM 1
and 2 go off.
Day PROG: With this parameter, we can decide on which days we
want programs 1 and 2 to be activeTo set this parameter
proceed as follows: set the day desired (days are Monday, Tues-
day,...
) with button P5 and with button P4 select the value ON-
OFF: if we set OFF, the programming set will not be activated on the
day desired, if ON is selected, the programming will be valid. At the
end of the programming press P6 and pass on to the next parameter.
POWER PROG: This parameter indicates the stove's power at the
time of ignition with CHRONOTHERMOSTAT.
TEMPERATURE PROG: This parameter indicates the ideal tempera-
ture you can reach in the room in which the stove is installed during
start-up with CHRONOTHERMOSTAT active. This setting is written
over the one set in manual work conditions.
ON - OFF
INDICATION
EXAMPLE
If you want the stove to switch ON at 6:00 am and switch OFF at 8:30
am (Program 1) and you want to set a room temperature of 21 °C and
to reach such a temperature with power 4, the steps to follow are:
At this point the user decides that his programming will be active on
specific days of the week such as Monday and Wednesday, while it is
de-activated on all other days.
The settings to be made will be as follows:
DAY DESIRED
Display this screen as described in
chapter 7.1.7. Set the time desired for
PROG - 1 to go on with buttons P1 and
P2. Press button P7 to confi rm. In the
case of error, press P7 to go back one
step.
Set the time desired for PROGRAM 1
to go off with buttons P4 and P5. Press
button P6 to confi rm.
Set the day on which we want PROG 1 to
be active or not active with button P5 (in
this case 1, i.e. Monday). At this point, set
the value on/off with button P4 which ac-
tivates/deactivates PROG -1 (in this case
ON, that is programming on).
SUMMARIZING, ON MONDAY THE
STOVE WILL SWITCH ON AT 6.00 A.M.
AND SWITCH OFF AT 8.30 A.M.0
Confirm with key 7 to go on to the next screen. At this point select the
power of PROG - 1.
After selecting the power you can select the room temperature you
ON TUESDAY THE STOVE WILL
NOT BE SWITCHED ON
ON WEDNESDAY THE STOVE
WILL BE SWITCHED ON AT 6.00
A.M. AND SWITCHED OFF AT
8.30 A.M.
ON THURSDAY THE STOVE
WILL NOT BE SWITCHED ON
ON FRIDAY THE STOVE WILL
NOT BE SWITCHED ON
ON SATURDAY THE STOVE WILL
NOT BE SWITCHED ON
ON SUNDAY THE STOVE WILL
NOT BE SWITCHED ON
Set the desired power for
PROG - 1 with buttons P1 and P2.
Pag.21