Herunterladen Inhalt Inhalt Diese Seite drucken

Description Of Alarms - Ravelli 500 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39

12. DESCRIPTION OF ALARMS

WARNING
The pellet tank is empty
PELLETS FINISHED
The ratiomotor does not load pellets.
ALARM
No pellet loading
No electricity supply during working phase
BLACK - OUT
The pellet tank is empty.
NO IGNITION ALARM
Setting of pellets and of intake during ignition phase insuffi cient.
The resistance for lighting is defective of not in position
The pellet tank is empty.
FLAME ANOMALY
ALARM
Bad setting of pellet and air on ignition in phase
EXTRACTOR REVS
The revolution of smoke fan lowering morenthe 15% of speed to fan
ANOMALY ALARM
congestion
Smoke extractor encoder is not functioning or not correctly connected
ALARM FAN BROKEN
No electricity supply to smoke extractor
The smoke extractor is blocked
The combustion chamber is dirty
DEPRESSION ALARM
The fl ue is blocked
The vacuum switch is malfunctioning
The thermostat with manual reset has intervened
The centrifugal fan is defective
THERMAL SAFETY
DEVICE ALARM
Combustion in the fi re pot is not optimal
SMOKE
Combustion in the fi re pot is not optimal
OVER-TEMPERATURE
The centrifugal fan is defective
ALARM
SMOKE SENSOR
The smoke sensor is malfunctioning
ALARM
The smoke sensor has been disconnected from the board
SCREW BLOCKAGE
The screw is not loading the pellet.
ALARM
By pressing the button P3 on the display, the alarm can be reset.
Try and repeat lighting after the cooling phase.
REASON
Unscrew the protection cap and
press the button to reset the
thermostat alarm.
SOLVING
Check whether there are pellets in the tank
Empty the tank to check that no objects have fallen inside which could prevent the correct
functioning of the screw
Regulate the pellet setting
If the problem continues, contact the area Technical Assistance Centre.
Press the off button and repeat switching on the stove
If the problem continues, contact the area Technical Assistance Centre.
Check if there are pellets inside the tank.
Contact local Technical Assistance Centre.
Contact local Technical Assistance Centre.
Ceckis pellet is in the hopper
Contact local Technical Assistance Centre.
Contact local Technical Assistance Centre.
Contact local Technical Assistance Centre.
Contact local Technical Assistance Centre.
Contact local Technical Assistance Centre.
Follow the cleaning operations of the stove as per the instructions in the booklet
Check that the fl ue is clear and clean
Please contact local Technical Assistance Centre.
Reset the thermostat pressing the button on the back of the stove (see Fig. below).
Please contact local Technical Assistance Centre.
Switch off the stove, clean the fi re pot and regulate combustion with the setting of the pellets.
If the problem continues, contact the area Technical Assistance Centre.
Switch off the stove, clean the fi re pot and regulate combustion with the setting of the pellets.
Contact local Technical Assistance Centre.
If the problem continues, contact the area Technical Assistance Centre.
Please contact the local Technical Assistance Centre
Please contact the local Technical Assistance Centre
Please contact the local Technical Assistance Centre
Pag.25

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis