Herunterladen Inhalt Inhalt Diese Seite drucken

Description Of The Symbols And Displays; Symbols; Description Of Functions; Modification Of Operating Power - Ravelli 500 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39
want in that room, irrespective of the one set in the room set during
manual running. As soon as the room temperature reaches the set
value, the stove goes on to MODULATE or COMFORT CLIMATE (if
activated).
Carry out the same operations, changing times and days of
activation for PROG-2 as well.
!
!
USING THIS MODE, YOU HAVE TO MAKE SURE EACH
TIME THAT AFTER THE STOVE IS AUTOMATICALLY
SWITCHED OFF, THE FIRE POT REMAINS CLEAN IN OR-
DER TO GUARANTEE CORRECT AUTOMATIC IGNITION.

8. DESCRIPTION OF THE SYMBOLS AND DISPLAYS

8.1. Symbols

CLOCK
STOVE STATUS
9. DESCRIPTION OF THE FUNCTIONS
9.1. Modification of the working power
To modify the working power, press button P5 to enter the appropri-
ate menu and with buttons P1 and P2 set the desired power from 1 to
5. By increasing the power, the consumption of pellets and the speed
of the exchanger fan increase. The power setting cannot be modified
in the MODULATION WORK phase.

9.2. Modulation

During the working phase, the aim of the stove is to reach the ambient
temperature set; when the setting is reached, the stove will function in
MODULATION WORK mode. During this phase, consumption of the fuel
will be minimal and the ambient fan will function at minimum power.

9.3. Comfort clima

To access this function, press P4 for four seconds.
When room temperature is reached, the electronic board reduces
pellet consumption to the minimum activating the modulation phase,
after which the stove checks if this temperature is maintained for a
pre-established period of time and if this happens, it passes auto-
matically to ECO STOP (the stove goes out).
Pag.22
Use keys P1 and P2 to set the
required temperature.
Press P7 to confirm.
CHRONOTHERMOSTAT
WORKING POWER
AMBIENT TEMPERATURE (TAKEN IN THE REMOTE
CONTROL POSITION)
to activate it, press button P5 setting a value
other than OFF and the following strings will
appear on the display
The value set (in this case 2) has activated the
Comfort Clima function.
FUNCTIONING:
The value sets the temperature the stove goes
back on again. Example:
- room temperature set at 21°
- Comfort Clima value set at 2
with this setting, the stove will switch off when
21°C is reached and will be switched back on
when the room temperature is 18°C (21°C – 2
– 0,5 = 18°C). The following strings will appear
in sequence on the display:
N.B.: The functioning of the stove in COMFORT CLIMATE mode
can start up the phase of ignition and switching off several
times through the day: this can compromise the duration of the
resistance for the automatic ignition of the stove.
!
!
USING THIS MODE, YOU HAVE TO MAKE SURE EACH
TIME THAT AFTER THE STOVE IS AUTOMATICALLY
SWITCHED OFF, THE FIRE POT REMAINS CLEAN IN OR-
DER TO GUARANTEE CORRECT AUTOMATIC IGNITION.
9.4. Modifications of the room temperature setting
The modes of functioning of the stove with the ambient thermostat
activated can be divided into two types:
ambient thermostat included in the remote control
with external thermostat (not supplied)
Comfort Climate mode
To access the menu press P4, and set the temperature using keys
P1 and P2.
AMBIENT THERMOSTAT MODE INCLUDED IN THE REMOTE
CONTROL
The display is fitted with an ambient thermostat. The recorded tem-
perature is visible on the display (see par. 8.1).
EXTERNAL THERMOSTAT MODE (NOT SUPPLIED)
If an external thermostat is used, correctly connected to the board
as shown in the electric wiring diagram (see page 25), the room tem-
perature will no longer be shown on the display but T ON. The room
temperature will be regulated directly by the wall-mounted thermo-
stat. When the temperature set on the display is reached, MODULA-
TION WORK will appear and in this case the stove will reduce the
consumption of pellets to a minimum, reducing the heating power to
a minimum.
N.PEL.
N.H2O
N.AMB.
1
2
3
4

9.5. Setting pellet-air mixture

The pellet-air blend setting makes it possible to regulate smoke
suction and the quantity of pellet loaded in a simple way. This
allows combustion to be regulated according to the stove's draught
and the hardness of the pellet. To access regulation press key
P6.The following strings will appear on the display:
The modulation phase is reached, as the
set room temperature has been reached. If
the temperature is maintained for about
4 minutes, the stove will activate the
switching off phase.
After the switching off phase, the display
will show ECO STOP. The stove will re-
main in this state until the temperature
drops to 18°C and only then will the ignition
phase be restarted.
TERM.
-TC1+
RED
BLUE
TERM.
-TC1+
5
6
7
8
9
10
ROOM
SMOKE PROBE
TERMOSTAT

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis