GB Reset/Technical data
5. Reset
For resetting the motor please use the setting switch for electronic drives.
Both end positions have to be set, so the movement isn't interrupted twice during
operation.
By pressing the bottom E for 1 second the drive will be put into the automatic setup
mode. Restart setting the end positions (4.4.1. to 4.4.3.).
6. Technical data
Series
1/6
1/10
2/7
2/10
2/15
2/20
2/30
2/40
2/50
Not all drive types are available in all series and torques. The motors have a 3 m power
line by default.
Information for all drive types:
Nominal voltage:
Safety class:
Operating time:
Subject to change without prior notice!
7. General declaration of conformity
SELVE GmbH & CO. KG company, hereby declares that the SEL Plus and SES are in
conformity with the basic requirements and other relevant provisions of the Directive
73/23/EWG and 89/336/EWG. The declaration of conformity can be looked up at
www.selve.de.
Rotation
Torque
speed
6 Nm
15 Rpm
10 Nm
15 Rpm
7 Nm
17 Rpm
10 Nm
17 Rpm
15 Nm
17 Rpm
20 Nm
17 Rpm
30 Nm
17 Rpm
40 Nm
17 Rpm
50 Nm
12 Rpm
230 V AC/50 Hz
IP 44
4 min.
Power Input
0.45 A
0.45 A
0.41 A
0.45 A
0.66 A
0.75 A
0.95 A
1.50 A
1.50 A
28
Output
105 W
105 W
95 W
105 W
152 W
172 W
220 W
345 W
345 W