3. Initial operation
3.1 Mounting of the drinker
The valve is suitable for a water pipe pressure up to ca. 5 bar.
For water pressure higher than 5 bar a pressure-relief valve needs to be mounted to avoid
dysfunction. The ideal setting of the pressure-relief valve is at ca. 3 bar.
For pipe mounting please use Lister fixing attachments.
For watering systems, in particular when heating water conduits, a safety pressure control
valve should be installed.
Only use little tightening tape for the thread of the connection pipe and the dummy plug of
the drinker.
Water conduit, blind plug and valve are only to be hand-screwed.
When connecting pipes to the drinkers pay attention to cleanliness (no residues such as
metal spill, sand etc. inside the pipe).
De-aerate pipe well!
3.2 Instructions for use and inspections
The inappropriate use of electrical units, in particular of animal husbandry products, involves
certain risks!
Prior to bringing your heatable drinker into service pay attention to the following risk
avoiding measures:
The voltage of the type plate and the mains voltage have to be in accordance.
Attention: The SB 112 H/24 RBH Volt drinker may only be operated in connection with a safety
low voltage transformer of max. 24 Volt.
All installation, repair and maintenance works may only be carried out by authorized
qualified technical staff.
The connection lead has to be installed in such away that it is out of reach for animals.
The end of the connection cable (plug or junction box), however, must easily be accessible
for the user.
The unit has to be kept free from dust and impurities.
Clean the unit only with a soft cloth or a cloth that is moisturized with soap water.
This should be free from benzine or solvents as they may affect or damage the plastic.
Check your watering installation in regular intervals; damaged units or feed pipes should not
be used.
Switch your watering system off from the current during the non heated period (e.g.
summer).
Declaration of conformity
This unit is in conformity with the requirements of the following EU-Directives:
2006/95/EG

Werbung