Herunterladen Inhalt Inhalt Diese Seite drucken

BOMANN WA 7192 Bedienungsanleitung, Garantie Seite 38

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Inlet filter at the tap
Clean the filter when not enough water is supplied
with opened water valve.
 Unscrew the inlet hose from the water valve.
 Wash the inlet filter under running water. Recon-
nect the inlet hose firmly.
Inlet filter at the appliance
Clean the filter regularly, approximately every one to
three months.
 Unscrew the inlet hose from the appliance back.
 Clean the filter with a small brush.
 Reconnect the inlet hose firmly.
Cleaning the filter of drain pump
CAUTION:
The appliance must never be used without the filter.
The foreign object trap in the drain pump prevents
rinsed-out parts from blocking the drain pump sys-
tem. Clean the pump regularly, approx. once a
month; depending on use.
 Open the maintenance cover in the base of the
unit. Caution! For this, the use of a tool could be
necessary.
 Place a drip tray under to catch possible leaking
water.
 Turn the cap counterclockwise. Look for leaking
water! Turn the filter not completely out!
 Interrupt the water flow by turning the filter clock-
wise again.
 If the draining process is completed, turn out the
filter completely.
 Take off the filter and remove any dirt and foreign
objects.
 Insert the cap again and make sure it is tightened
well and no water can escape.
 Close the maintenance cover.
Freezing protection
If the appliance is out of operation and exposed to
temperatures below zero, observe the following
measures:
 Disconnect the unit from the power supply.
 Close the water supply and remove the inlet hose
from the water valve.
 Drain the water from the supply hose and from the
water valve.
 Reconnect the supply hose to the water valve.
38

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis