3.
MULTIPORT VALVE FUNCTIONS
CAUTION!
Never change the valve position while the pump is on, this could cause serious damage to the filter
and will cancel the guarantee.
16/40
2020/12 - Indice de révision : D - Code : 26625
FILTRATION :
Normal position of the valve. The water coming from the pump
passes from the top to the bottom of the filter and is then directed to the pool.
WASTE :
The water coming from the pump is directed to the waste outlet without
passing through the filter.
CLOSED :
No water circulation in this position. Make sure that the pump is never
operated in this position.
BACKWASH :
The water coming from the pump passes from the bottom to the top
of the filter to escape through the waste outlet washing away the impurities retained
by the filter.
RECIRCULATE :
The water coming from the pump is directed to the pool without
passing through the filter.
RINSE :
The water coming from the pump passes from the top to the bottom of the
filter and escapes through the waste outlet.