Herunterladen Diese Seite drucken

Sharp FZ-80SEF Anleitung Seite 3

Austauschfilter für den luftreiniger wie filter ausgetauscht wird

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
2
Install the filters
1
Take the HEPA filter out of its
plastic bag, and secure it in the
filter frame with the indicated
'FRONT' label facing outwards.
(One each top and bottom)
Insert the HEPA filter with its 'removal tags'
facing outwards.
If it is installed the wrong way round, it will
not work.
2
Take the deodorizing filter out of
its plastic bag, and place it over
the HEPA filter with the black side
facing up. (One each top and bot-
tom)
Attach it with the 'removal tags'
protruding from the filter frame.
3
Insert the filter fixers into their
sockets. (Two each top and bot-
tom)
4
Insert the four tabs on the pre-
filter into the square notches in
the filter frame. (Two each top
and bottom)
5
Fill in the usage start date on the
Date label affixed on the main
unit.
Use the date as a guide for the filter re-
placement period.
6
Holding the filter frame by its han-
dle, secure it to the main unit.
Recess both the top and bottom handles
into the main unit.
7
Insert the two protruding catches
located on the back of the front
panel into their housings on the
main unit, and affix the front panel
to the main unit using the top
screws (one each left and right).
HEPA filter (white)
Deodorizing filter (Front: black)
Microbial control filter (Back: white)
Filter frame
Removal tag
Removal
tags
Filter fixers
Tabs (X4)
Protruding catches
Back of the front panel
Front panel
E-2
Sockets
Square
notches
Date label
Housings
Phillips screws

Werbung

loading