Herunterladen Inhalt Inhalt Diese Seite drucken

Oase Varionaut 150 Gebrauchsanleitung Seite 19

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Addressing via DMX
DMX (Digital Multiplex) is a standardised digital transmission protocol used in stage and event equipment as well as in
many Oase components.
The DMX Channel and the mode can be changed by means of a DMX controller from OASE. Read the corresponding
operating instructions.
Description
Serial No. (SN)
Product ID
Version No.
DMX Channel
Configuration mode
Config. mode
1
Operation
Overview DMX parameters
Two channels are required for controlling the pump. The first channel is defined via the OASE DMX controller. The se-
cond channel is incremented and defined automatically.
• The first possible DMX starting address is 1.
• The last possible DMX starting address is 511.
Channel
DMX Channel + 0
DMX Channel + 1
Reset error
How to proceed:
1. Use DMX Channel + 0 to set a value between 240 and 255.
2. Use DMX Channel + 0 to set a value between 0 and 10.
– The error has been reset.
3. Access the pump with the desired value.
Information on show programming
Switch-on/switch-off cycles
• Only switch on the pump max. 1 x per minute.
• Wait for at least 10 seconds between switching off the pump and switching it on again.
Switch-on sequence:
Step
Description
1
Pump rotational speed set to minimum
2
Control mode ON
3
Waiting time 1-3 seconds
4
Effect
Switch-off sequence:
Step
Description
1
Pump rotational speed set to minimum
2
Pump OFF
The DMX-Channel + 0 (Control Channel) may not be changed during a show. The effects are exclusively programmed
via the DMX-Channel + 1 (Speed Channel).
Value
Enter the unit serial number. The serial number  is indicated on the label next
to the type plate.
121
1
The factory-set DMX channel  is indicated on the label next to the type plate.
1 = Set DMX starting address.
Description config. mode
Set DMX channel
Description
Pump OFF
Control mode (do not use)
Speed control
Speed control, characteristic line compensation
Not in use
Reset error (→ Reset error)
Speed default value
Transfer value
Description transfer value
Function
x
Speed
Value
0 ... 10
11 ... 49
50 ... 99
100 ... 149
150 ... 239
240 ... 255
0 ... 255
Channel
DMX Channel + 1
DMX Channel + 0
DMX Channel + 1
Channel
DMX Channel + 1
DMX Channel + 0
- EN -
x + 0
x + 1
Values
0
50 ... 99
1 ... 255
Values
0
0 ... 10
19

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

50665