3.1 Installation

Switch off the splitting saw be-
fore connecting to the mains
power supply!
Improper use of the unit can
lead to parts being damaged!
Installation work may only be
carried out by authorised spe-
cialist personnel.
Caution!
Trip hazard!
Keep all cabling outside busy
working areas.
Important information, e.g.
technical data sheets, drawings
and parts lists can be found in
annex.

19. Electrical connection

The splitting saw is operated with electrical en-
ergy and must be connected to the mains
power supply by a qualified electrician in ac-
cordance with statutory regulations and the reg-
ulations of the local public utility.
 Prior to connecting the safety isolating trans-
former to the primary side, check the operat-
ing data of both the mains and the trans-
former circuitry.
 When electrically connecting the controller
to the transformer's secondary side, ensure
that the wiring complies with section "Cross-
sections of lines".
 Refer to the labelling and the wiring diagram
to attach the connection cables of the ma-
chines.
 The machines have been designed compli-
ant to VDE directives and the EC machinery
directive. For reasons of operating safety,
you are not allowed to modify or reconstruct
the machine and the safety equipment (e.g.
lid guard, two-hand safety circuit) in particu-
lar.
Schmid & Wezel
Check the direction of motor rotation.
Direction of saw belt motion
Fig. 1 Direction of rotation / motion of the mo-
tor / saw belt

20. Spring balancer

The machine must always be operated in com-
bination with a weight relief system (spring bal-
ancer). Use a sliding crane trolley to mount the
spring balancer on an element above the work-
ing area or on the ceiling. For details about how
to fine-tune the spring balancer refer to section
"Spring balancer adjustment".
Suspend the splitting saw top-heavy, if possi-
ble. The vertical position can be adjusted, if
necessary.
In view of the considerable weight, there is a
danger of the machine slipping or falling when
attaching or releasing the weight relief system.
Pay attention that the device does not catch on
the snap hooks or the hook of the splitting saw.
Work cautiously!
When the splitting saw is not in use, store it so
that there is no risk of accidental contact with
the saw belt as this may cause injury.

21. Water connection

The machine is designed for automatic cleaning
using cooling and hot water. The water connec-
tions are labelled "C" (cold water, blue) and "H"
(hot water, red) respectively.
Water supply is actuated by solenoid valves set
by the controller. Timing relays allow the clean-
ing cycle to be adjusted. We recommend in-
stalling manual check valves upstream the sole-
noid valves.
Seite / Page
19 / 33
Direction of
motor rotation
The hot water used to
rinse/clean the inside of the
splitting saw must be below
70 °C hot!
Risk of injury!
Risk of scalding!
Mind not to come into contact
with the hot water!