Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
The exhaust air line should be as short and
straight as possible.
To avoid excessive noise or a reduced extraction
capacity the diameter of the exhaust air pipeline
should not be less than
Use or form only large radius bends. Small radius
bends reduce the extraction capacity of the hood.
Use only smooth pipelines or flexible hoses of
non-flammable materials for the exhaust air
pipeline
If the exhaust air pipeline is horizontally routed,
there must be a minimum gradient of 1 cm per
metre or an inclination angle of 2°.
C
Otherwise condensation water could run into the
extractor hood motor.
If the exhaust air is directed into an exhaust air
duct, the end of the entry fitting must be directed
in the direction of flow.
If the exhaust air pipeline is routed though cool
rooms, lofts etc. there can be a large temperature
drop within the individual parts of the pipeline,
resulting in sweating or condensation water
production. This renders outlet pipeline insulation
necessary.
In some cases a condensation water barrier must
be installed in addition to adequate insulation.
(these are available from leading building material
suppliers).

13. Guaranty

Please take note of the general guarantee terms and the
guarantee period, stated in the attached guarantee card.
If the appliance documentation does not include a
guarantee card, please contact your dealer.
There is no Guarantee on light fittings.
The manufacturer is not responsible for any
faults occurring through non-compliance with the
above information and provisions.
The manufacturer is constantly engaged in the
further improvement of his products. Please note
that products are subject to changes in form,
equipment and the applied technology.
fi201203
Operating- & Installation Instruction Cooker Hoods
120
mm.
(Fig. C)
7
GB

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis